floor stiffness 360 or 480

TJI 110, 210, 230, 360, 560 Joists Specifier's Guide - Weyerhaeuser

codes' static deflection and looks at the entire floor system. At 45 points, customer satisfaction. Live Load is based on joist deflection of L/480.

Get Price

Floor Truss Span Tables - Truss Specialists

These allowable spans are based on NDS 91. Maximum deflection is limited by L/360 or L/480 under live load. Basic. Lumber Design Values are F =2000 psi F.

Get Price

Flooring -- what is 1/360 deflection? - HomeOwnersHub

They say the maximum floor joist should be 16" on center with 'a maximum deflection of 1/360 of the span, at midpoint.' What does this mean?

Get Price

Deflection Limit State - A Beginner's Guide to Structural Engineering

This simplistic criteria puts a limit of the span divided by 360 on the. and institutional applications where increased floor stiffness is desired.

Get Price

How To Select TJI Floor Joist Sizes - Home Construction Improvement

The minimum deflection criteria of L/360 will usually control.. So my recommendation is to select your floor joists based on L/480 deflection criteria.

Get Price

TJI 110, 210, 230, 360, and 560 Joist Specifier's Guide - Parr Lumber

span-rated, glue-nailed floor panels for deflection only .. code minimum of L/360 (or even the more restrictive limits of L/480) may disappoint many.

Get Price

Commercial Floor Loads - Pacific Woodtech Corporation

Building codes typically require L/360 for live load. Experience has shown that live load deflection limits of L/480 at 40 psf for residential floors and L/600.

Get Price

9 1/2" I-joist or 11 7/8"? - Houzz

To increase the floor stiffness you would need to use an 11 7/8" deep I-Joist or space. Live load deflection of L/360 is acceptable, and L/480 is better.

Get Price

Deflection in TJI joists over long span - Houzz

The first floor joists on my plans are calling for 16 inch (in height) TJI. what "deflection limit" was used when the joists were sized (L/360, L/600,.

Get Price

Deflection limits.not just L/360 - Structural engineering. - Eng-Tips

L/480 seems to keep floors under control. vibration, etc.. If you have walls or partitions on the floor in question - these help a LOT in.

Get Price

Deflection performance criteria for floors - US Government.

have a deflection greater than 1/360 of the span for a prescribed liveload.. who suggested a maximum deflection of L/480to prevent cracking in plastered.

Get Price

780 CMR 55.00 - Mass.gov

the floors for all buildings including the floors of. Deflection criteria: L/480 for live loads, l/360 for total loads. b. Floor dead load - 10 psf.

Get Price

Serviceability design of residential wood framed floors in Canada

In the same way, the L/360 or L/480 override on uniform load deflection, which tended to govern floors with concrete topping, also inadequately compensated for.

Get Price

Tips for Avoiding Floor Vibrations

Design Guide 11 Floor Vibrations due to Human Activity.. compute the L/360 deflection limit live load in the Steel Joist Institute load tables.

Get Price

Bailey C Joist Span Tables and Details

FLOOR JOIST SPAN LIMITATIONS. Joist Member. Yield. Strength. Fy(ksi). 15 psf Dead Load 40 psf Live Load. TL Deflection = L/240, LL Deflection = L/360.

Get Price

Deflection, an Installer's Dilemma

Oct 1, 2006. With ceramic floors, if the floor joists bounce, or deflection between the. Most people don't understand what an l/480 or l/360 means but.

Get Price

Trusses vs. floor joists layout - explain please. | The Garage Journal

Feb 23, 2017. ForceFed70 and ssdave - on your trusses - did you build for l/360 or l/480? wssix99 - option 1 was your traditional attic truss - not floor.

Get Price

Technical Guide for Residential Construction

or 24 oc APA RATED STURD-I-FLOOR, or equal, glued and nailed to the top flange. 4. Live Load deflection is limited to L/480 or L/360 for simple spans as.

Get Price

Technical Guide for Residential Construction - LP Building Solutions

Use only 2-1/2" or 3" nails when securing an LPI floor or roof joist to its. To design for an L/360 live load deflection, multiply the Live L/480.

Get Price

Deflection performance criteria for floors - Nvlpubs.​nist.​gov

have a deflection greater than 1/360 of the span for a prescribed liveload.. who suggested a maximum deflection of L/480to prevent cracking in plastered.

Get Price

LVL User's Guide - West Fraser

Unfactored live load resistance is based on a deflection of L/360.. Load (LL) L/360. 3100Fb-2.0E West Fraser™ LVL — FLOOR or ROOF (Standard Term).

Get Price

Wood Framing For Tile Flooring - Structural Support

Manufacturers of I-beam type floor joists (such as Trus Joist / Weyerhauser and Georgia Pacific) have recommended a deflection limit of Span / 480 for live.

Get Price

Learn more about open joist - Truss Systems, Inc.

OPEN JOIST floor trusses are already engineered and built to trimmable stock. 9-V." Depth Maximum Live Load Deflection - L/360 and L/480, 1-%" Minimum.

Get Price

Nordic Joist - Nordic Structures

For floor or roof applications with L/360 live load deflection, multiply L/480 value times 1.33. 9. For double joists, double the table values and connect joist.

Get Price

Understanding Trus Joist Pro Ratings and Minimum Deflections by.

For floor joists a live load deflection limit of L/360 and a total load deflection. floors for homeowners a deflection limit of L/480 is commonly used.

Get Price

L/360, l/480, l/?? - Ceramic Tile Advice Forums - John Bridge Tile.

May 21, 2010. What is 480 or what ever? I also know they are standards of deflection.. The L360 means that the floor deflects 1/360th of the span

Get Price

Bouncy manufactured I joist floors - InspectionNews - Home Inspection

Jan 7, 2014. In the past the L/480 criteria has been widely used to provide stiffer. a dead load of 20 psf, and an allowable deflection of L/360.

Get Price

Alpine Truss Floor Truss Guid. - Alpine ITW

compared to traditional joist construction, manufactured wood floor truss systems are better,. Maximum deflection is limited by L/360 or L/480 under.

Get Price

SpaceJoist Open Web Floor Joist Guide - Alpine

SpaceJoist: Residential Floor Span Charts 4 Up to 12" may be. 40-10-5 420 Series Depth Deflection 24" O.C. 19.2" O.C. 16" O.C. 12" O.C. 9¼" L/480 1.

Get Price

Supporting a Top-Quality Ceramic Floor | Builder Magazine

Deflection of the subfloor between the joists under a point load should be even less—perhaps as slight as L/480 or L/1080 for brittle stone tile. To get that.

Get Price

Finnframe Floor System Brochure - Metsä Wood

360, 400. 220, 220,. 240, 300,. 360, 400. 240, 300. 240, 300. The most important factor influencing floor performance is stiffness.

Get Price

I-Joists - Armchair Builder

What are your alternatives for floor framing?. Code is L/360…so L/480 allows less deflection when weight is applied; Check the installation with the.

Get Price

View Load Tables - Imperial Building Products

Shoring and Curing Requirements for Composite Floor Joists .. For L/360 deflection criteria, multiply allowable span by factor = 1.10.

Get Price

Specifier's Guide for Weyerhaeuser Edge and Edge Gold Floor Panels

Weyerhaeuser Edge™ oriented strand board (OSB) floor panels help builders get an edge on. (1) Deflection calculation based on L/360 deflection limit.

Get Price

PERMA-STRAIGHT I - Stark Truss

The deflection values do not reflect any additional stiffness due to composite action.. design live load to either the L/480 or L/360 column as needed.

Get Price

RigidLam® LVL Floor Span Tables - Roseburg Forest Products

1-1/2” 1.3E RigidLam LVL Floor Spans - 40 psf Live Load, 12 psf Dead Load. Live Load deflection is limited to L/480 or L/360 as indicated in the tables.

Get Price

Wood Floor Trusses Guide - Cascade Manufacturing Company

compared to traditional joist construction, manufactured wood floor truss systems are better,. Maximum deflection is limited by L/360 or L/480' under.

Get Price

Specifier's Guide for Deep Depth TJI 360, 560 and 560D Joists

center span-rated, glue-nailed floor panels for deflection. L/480. Total. Load. Live. Load. L/480. Total. Load. 18". 360.

Get Price

I-Joist Residential Design Manual - Truss Fab Inc

Using floor deflection of L/480 instead of the code minimum of L/360. • Gluing and nailing the sub-floor to the joists. • Attaching gypsum board to the bottom.

Get Price

Chapter 5 Floors - UpCodes

Floor framing shall be designed to meet joist deflection requirements in accordance. Deflection criteria: L/480 for live loads, L/240 for total loads.